GPS Controlled Crystal Ocillator


(EFC) - Electronic Frequency Control

(PU) - Predicted Uncertainty

(TI) - TIme Interval Value

(LPF) - Lo-Pass Filter of TI Data

(SC) - Satellite count
Power-on time
Days Hrs Mins Secs
           HEWLETT-PACKARD,Z3801A,3542A05759,3543-A. Life count: 43072
SYNCHRONIZATION ............................................. [ Outputs Valid ]
SmartClock Mode ___________________________   Reference Outputs _______________
>> Locked to GPS                              TFOM     3             FFOM     0
   Recovery                                   1PPS TI -13.6 ns relative to GPS
   Holdover                                   HOLD THR 1.000 us
   Power-up                                   Holdover Uncertainty ____________
                                              Predict  2.3 us/initial 24 hrs
                                                
ACQUISITION ............................................ [ GPS 1PPS CLK Valid ]
Satellite Status __________________________   Time ____________________________
Tracking: 5        Not Tracking: 3            GPS      11:05:39     27 Apr 1998
PRN  El  Az   SS   PRN  El  Az                1PPS CLK Synchronized to GPS Time
  2  66  34   55   * 6  Acq .                 ANT DLY  0 ns
  5  36 145  110    19  11  78                Position ________________________
 12  86 343  211    24  23 212                MODE     Hold
 25  44 316  200                              
 29  26 290  116                              LAT      N  34:08:18.207
                                              LON      W 118:23:19.678
ELEV MASK 10 deg   *attempting to track       HGT              +214.82 m  (MSL)
HEALTH MONITOR ......................................................... [ OK ]
Self Test: OK    Int Pwr: OK   Oven Pwr: OK   OCXO: OK   EFC: OK   GPS Rcv: OK